Cabinet ESP Air Purifier Module for AHU & FCU | KYC285K2 | ASHRAE 52.2, 25W Ultra-Low Power

Cabinet ESP Air Purifier Module for AHU & FCU | KYC285K2 | ASHRAE 52.2, 25W Ultra-Low Power

Regular price $620.00 USD
Regular price $498.00 USD Sale price $620.00 USD
Sale Sold out
Shipping calculated at checkout.
Configuration
Quantity
96.3% – 97.0%
PM0.3–1.0 (ASHRAE 52.2)
25 W
Ultra-Low Power @ 5100 m³/h
93.5%
Microbial Kill (Class A)
Filter-Free
Washable ESP + Plasma

Modular ESP Purification for AHU/MAU/FCU Ductwork: The KINYO KYC285K2 (KYC series) is engineered as a splice-together cabinet module for central air conditioning AHU, MAU, and FCU return air or fresh air blower inlet ducts. Multiple modules combine seamlessly to scale airflow from 500 up to 100,000 m³/h, delivering independently verified PM0.3–10 capture, microbial sterilization, and ultra-low pressure drop without disposable filter replacement.

Performance & Verification
Parameter Result Notes
PM0.3–1.0 Removal (E1) 96.3% – 97.0% Third-Party Tested (ANSI/ASHRAE 52.2-2025)
PM1.0–3.0 Removal (E2) 97.4% – 97.7% Third-Party Tested (ANSI/ASHRAE 52.2-2025)
PM3.0–10.0 Removal (E3) 97.6% – 98.5% Third-Party Tested (ANSI/ASHRAE 52.2-2025)
Microorganism Sterilization 93.5% (Ew > 90) Third-Party Tested (GB/T 34012 Class A)
Formaldehyde Removal > 94% Third-Party Laboratory Tested
VOC Removal > 92% Third-Party Laboratory Tested

Note: Performance results certified by Jianke EET Co., Ltd. (Report No. EET-2026AC-0066 (E), CNAS L1045 / ILAC-MRA Accredited) under ANSI/ASHRAE Standard 52.2-2025 and GB/T 34012-2017. Actual performance may vary depending on airflow, pollutant concentration and installation environment. Official test reports and submittal sheets are available upon request.

Engineering Highlights
01. ANSI/ASHRAE 52.2-2025 Certified Efficiency
Independently verified counting efficiency exceeding 96.3% for E1 (0.3-1.0μm) and 98.5% for E3 (3-10μm), meeting stringent HVAC air-cleaning engineering requirements.
02. Ultra-Low Power Draw (25W @ 5100 m³/h)
Consumes only 25W even at full 3000 CFM (5100 m³/h) rated airflow, drastically cutting operational energy and building carbon footprint compared to motorized purification.
03. Washable & Zero-Consumable ESP Core
Industrial-grade electrostatic cell and plasma generator eliminate recurring disposable filter media replacement costs with zero secondary pollution.
04. Class A Microbial Inactivation
Verified 93.5% single-pass kill rate against Staphylococcus albus under ventilation system conditions, ensuring hygienic indoor air quality for commercial spaces.
Technical Data & Specifications
Model Series KYC285K2 / KYC285K1
Testing & Certifications ANSI/ASHRAE 52.2-2025, GB/T 34012-2017 (ILAC-MRA / CNAS Accredited Laboratory)
Purification Technologies Two-Stage Electrostatic Precipitation (ESP), Plasma Disinfection
Face Area Dimensions 670 × 480 mm
Airflow Capacity 500–100,000 m³/h (Modular Splice-Together)
Rated Power Consumption 25 W (@ 5,100 m³/h rated airflow)
Airflow vs. Resistance Gradient 19.4 Pa @ 1444 m³/h | 31.3 Pa @ 2039 m³/h | 127.6 Pa @ 5100 m³/h
Operating Voltage 110VAC/60Hz, 220VAC/50Hz
Control Method Auto Control by Airflow Sensor, Dry Contact Output for BMS
Cabinet Dimensions & Weight 372 × 568 × 285 mm / 720 × 570 × 285 mm | 25–30 kg
Safety Protection Cover-Open Power Off, 3s Arc-Spark Auto Alert & Shutoff, Cleaning Reminder
OEM / ODM Engineering Solutions
Custom airflow capacity, duct dimension adaptations, BMS dry contact integration, and test report / submittal sheet access for HVAC equipment engineers.