{"product_id":"kyog220v06","title":"High Voltage Power Supply for Commercial ESP \/ KYOG220V06 \/ 220VAC \u0026 Dual 8kV\/4kV 5W","description":"\u003cdiv style=\"max-width: 1000px; margin: 0 auto; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; color: #1e293b; line-height: 1.6;\"\u003e\n\u003c!-- Section 1: Core Metrics Bar --\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 12px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"border-top: 3px solid #1773b0; border-radius: 4px; padding: 12px 14px; background: #ffffff; border: 1px solid #e2e8f0; text-align: center;\"\u003e\n\u003cspan style=\"display: block; font-size: 11px; text-transform: uppercase; color: #64748b; font-weight: 600; letter-spacing: 0.5px;\"\u003eMax Rated Power\u003c\/span\u003e \u003cspan style=\"display: block; font-size: 20px; font-weight: bold; color: #0f172a; margin-top: 4px;\"\u003e5 Watts\u003c\/span\u003e \u003cspan style=\"display: block; font-size: 11px; color: #1773b0; margin-top: 2px;\"\u003eLow Energy Consumption\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 3px solid #1773b0; border-radius: 4px; padding: 12px 14px; background: #ffffff; border: 1px solid #e2e8f0; text-align: center;\"\u003e\n\u003cspan style=\"display: block; font-size: 11px; text-transform: uppercase; color: #64748b; font-weight: 600; letter-spacing: 0.5px;\"\u003eDual High-Voltage\u003c\/span\u003e \u003cspan style=\"display: block; font-size: 20px; font-weight: bold; color: #0f172a; margin-top: 4px;\"\u003e+8 kV \/ +4 kV\u003c\/span\u003e \u003cspan style=\"display: block; font-size: 11px; color: #1773b0; margin-top: 2px;\"\u003eIonizer \u0026amp; Collector DC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 3px solid #1773b0; border-radius: 4px; padding: 12px 14px; background: #ffffff; border: 1px solid #e2e8f0; text-align: center;\"\u003e\n\u003cspan style=\"display: block; font-size: 11px; text-transform: uppercase; color: #64748b; font-weight: 600; letter-spacing: 0.5px;\"\u003eOutput Current\u003c\/span\u003e \u003cspan style=\"display: block; font-size: 20px; font-weight: bold; color: #0f172a; margin-top: 4px;\"\u003e50 ~ 600 μA\u003c\/span\u003e \u003cspan style=\"display: block; font-size: 11px; color: #1773b0; margin-top: 2px;\"\u003eTrimmer Adjustable\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 3px solid #1773b0; border-radius: 4px; padding: 12px 14px; background: #ffffff; border: 1px solid #e2e8f0; text-align: center;\"\u003e\n\u003cspan style=\"display: block; font-size: 11px; text-transform: uppercase; color: #64748b; font-weight: 600; letter-spacing: 0.5px;\"\u003eAirflow Capacity\u003c\/span\u003e \u003cspan style=\"display: block; font-size: 20px; font-weight: bold; color: #0f172a; margin-top: 4px;\"\u003e\u0026lt; 1000 m³\/h\u003c\/span\u003e \u003cspan style=\"display: block; font-size: 11px; color: #1773b0; margin-top: 2px;\"\u003eCommercial ESP Units\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Section 2: Problem-Solution Lead Banner --\u003e\n\u003cdiv style=\"background: #f8fafc; border-left: 3px solid #1773b0; padding: 16px 20px; margin-bottom: 24px; border-radius: 0 4px 4px 0;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px 0; font-size: 16px; font-weight: bold; color: #0f172a;\"\u003eCommercial-Grade 5W Dual-Output High-Voltage Power Pack for Electrostatic Air Cleaners\u003c\/h3\u003e\n\u003cp style=\"margin: 0; font-size: 13px; color: #334155; line-height: 1.6;\"\u003eThe KYOG220V06 (KYA0044 series) high-voltage power supply delivers 5W of regulated dual high-voltage DC power (+8 kVDC for ionization and +4 kVDC for dust collection) designed for commercial electrostatic precipitator (ESP) units and HVAC air cleaning equipment handling up to 1000 m³\/h. Featuring patented voltage and current double closed-loop control technology, it maintains stable particle capture efficiency while suppressing harmful ozone generation. Encapsulated in black flame-retardant epoxy resin inside an 89×76×30 mm compact housing, it features built-in output short-circuit, overload, and 2–5s continuous arc-pull protection with a 0V\/5V remote diagnostic fault feedback signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Section 3: Performance \u0026 Verification (P\u0026V) Table --\u003e\n\u003cdiv style=\"margin-bottom: 24px;\"\u003e\n\u003ch3 style=\"font-size: 15px; font-weight: bold; color: #0f172a; margin-bottom: 12px; display: flex; align-items: center;\"\u003e\n\u003cspan style=\"width: 4px; height: 16px; background: #1773b0; display: inline-block; margin-right: 8px; border-radius: 2px;\"\u003e\u003c\/span\u003e Performance \u0026amp; Verification (P\u0026amp;V)\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; text-align: left; background: #ffffff; border: 1px solid #e2e8f0; border-radius: 4px; overflow: hidden;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f1f5f9; border-bottom: 1px solid #cbd5e1;\"\u003e\n\u003cth style=\"padding: 10px 14px; font-weight: 600; color: #334155; width: 35%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px 14px; font-weight: 600; color: #334155; width: 35%;\"\u003eResult \/ Accuracy\u003c\/th\u003e\n\u003cth style=\"padding: 10px 14px; font-weight: 600; color: #334155; width: 30%;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 500; color: #0f172a;\"\u003eDual High-Voltage Output Amplitude\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #334155;\"\u003e+8.0 kVDC \/ +4.0 kVDC (±5%)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #64748b;\"\u003eInternal Laboratory Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 500; color: #0f172a;\"\u003eContinuous Arc-Pull Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #334155;\"\u003e2.0 ~ 5.0 Seconds Cutoff Latency\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #64748b;\"\u003eInternal Laboratory Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 500; color: #0f172a;\"\u003eRegulated Output Current\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #334155;\"\u003e50 ~ 600 μA Continuous (Adjustable Trimmer)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #64748b;\"\u003eInternal Laboratory Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 500; color: #0f172a;\"\u003eMaximum Rated Power Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #334155;\"\u003e5.0 Watts Full Ionization Load\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #64748b;\"\u003eInternal Laboratory Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 500; color: #0f172a;\"\u003eFault Status Signal Feedback\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #334155;\"\u003eNormal: 0 VDC \/ Fault: 5 VDC\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #64748b;\"\u003eInternal Laboratory Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 500; color: #0f172a;\"\u003eDouble Closed-Loop Control Stability\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #334155;\"\u003eVoltage \u0026amp; Current Closed-Loop Circuit Control\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #64748b;\"\u003eInternal Laboratory Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 500; color: #0f172a;\"\u003eContinuous Operational Lifespan\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #334155;\"\u003e≥ 30,000 Hours Continuous Industrial Duty\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #64748b;\"\u003eInternal Laboratory Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 500; color: #0f172a;\"\u003eSafety \u0026amp; Regulatory Compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #334155;\"\u003eDesigned to meet CE \u0026amp; RoHS Directives\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #64748b;\"\u003eInternal Laboratory Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 11px; color: #64748b; margin-top: 8px; margin-bottom: 0; line-height: 1.5; font-style: italic;\"\u003eNote: Performance results were obtained under controlled laboratory conditions. Actual performance may vary depending on test conditions, airflow, pollutant concentration and installation environment. Test reports are available upon request.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Section 4: Engineering Highlights --\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(220px, 1fr)); gap: 12px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; border-radius: 4px; padding: 14px; background: #ffffff;\"\u003e\n\u003cspan style=\"font-size: 12px; font-weight: bold; color: #1773b0;\"\u003e01. Patented Double Closed-Loop Control\u003c\/span\u003e\n\u003cp style=\"margin: 6px 0 0 0; font-size: 12px; color: #475569; line-height: 1.5;\"\u003eContinuous voltage and current monitoring stabilizes ionization efficiency under shifting temperature, humidity, and particle loads while keeping ozone concentration strictly suppressed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; border-radius: 4px; padding: 14px; background: #ffffff;\"\u003e\n\u003cspan style=\"font-size: 12px; font-weight: bold; color: #1773b0;\"\u003e02. Active Arc \u0026amp; Short-Circuit Safety\u003c\/span\u003e\n\u003cp style=\"margin: 6px 0 0 0; font-size: 12px; color: #475569; line-height: 1.5;\"\u003eIntelligent protection circuit trips within 2–5 seconds during sustained dielectric flashovers or short-circuits, shutting off high voltage to protect ESP collector plates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; border-radius: 4px; padding: 14px; background: #ffffff;\"\u003e\n\u003cspan style=\"font-size: 12px; font-weight: bold; color: #1773b0;\"\u003e03. Remote Diagnostic Fault Output (0V\/5V)\u003c\/span\u003e\n\u003cp style=\"margin: 6px 0 0 0; font-size: 12px; color: #475569; line-height: 1.5;\"\u003eLow-voltage fault interface outputs 0VDC during normal operation and 5VDC upon fault trip, allowing building automation systems (BMS) or master controllers to monitor status in real time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; border-radius: 4px; padding: 14px; background: #ffffff;\"\u003e\n\u003cspan style=\"font-size: 12px; font-weight: bold; color: #1773b0;\"\u003e04. Compact Potted Industrial Housing\u003c\/span\u003e\n\u003cp style=\"margin: 6px 0 0 0; font-size: 12px; color: #475569; line-height: 1.5;\"\u003e89×76×30 mm compact profile fully encapsulated with vacuum-degassed epoxy resin, insulating high-voltage electronics against moisture, dust accumulation, and airborne oil mists.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Section 5: Technical Data \u0026 Specifications --\u003e\n\u003cdiv style=\"margin-bottom: 24px;\"\u003e\n\u003ch3 style=\"font-size: 15px; font-weight: bold; color: #0f172a; margin-bottom: 12px; display: flex; align-items: center;\"\u003e\n\u003cspan style=\"width: 4px; height: 16px; background: #1773b0; display: inline-block; margin-right: 8px; border-radius: 2px;\"\u003e\u003c\/span\u003e Technical Data \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; text-align: left; background: #ffffff; border: 1px solid #e2e8f0; border-radius: 4px; overflow: hidden;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155; width: 40%;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eKYOG220V06 (KYA0044 Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eProduct Category\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eCommercial Dual-Output High-Voltage Power Supply for ESP Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eCircuit Control Topology\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eVoltage and Current Double Closed-Loop Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eOperating Input Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eAC 180~250V 50\/60Hz (via Step-Down Transformer; 18VAC \/ 24VDC Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eDual High-Voltage DC Output\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003e+8 kVDC (Ionizer Stage) \/ +4 kVDC (Collector Stage) [Customizable]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eMaximum Rated Power\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003e5 Watts Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eRated Output Current\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003e50 ~ 600 μA Continuous (Trimmer Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eApplicable Airflow Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003e\u0026lt; 1000 m³\/h (Commercial Air Cleaners \u0026amp; HVAC Ducts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eDiagnostic Fault Feedback\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eNormal Operation: 0 VDC \/ Electrical Fault: 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eSafety Protections\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eOutput Short-Circuit, Overload, 2–5s Continuous Arc-Pull Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eEncapsulation \u0026amp; Enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eFlame-Retardant ABS Plastic Housing (Potted Black Epoxy Resin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003e89 mm (L) × 76 mm (W) × 30 mm (H) [CAD: 88.9 × 76.3 × 30.6 mm, Pitch: 80.0 mm]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eChassis Screw Mounting (Dual Integrated Side Mounting Tabs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f1f5f9; background: #fafafa;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eWiring Harnesses\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eYellow AC Input with Socket, 0V\/5V Signal Lead, Red (+8kV) \u0026amp; Black (+4kV) HV Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-weight: 600; color: #334155;\"\u003eCompliance Standards\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; color: #0f172a;\"\u003eDesigned to meet CE and RoHS standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- Section 6: Applications --\u003e\n\u003cdiv style=\"margin-bottom: 24px;\"\u003e\n\u003ch3 style=\"font-size: 15px; font-weight: bold; color: #0f172a; margin-bottom: 12px; display: flex; align-items: center;\"\u003e\n\u003cspan style=\"width: 4px; height: 16px; background: #1773b0; display: inline-block; margin-right: 8px; border-radius: 2px;\"\u003e\u003c\/span\u003e Recommended Applications \u0026amp; Equipment Integration\u003c\/h3\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 8px;\"\u003e\n\u003cspan style=\"border: 1px solid #cbd5e1; border-radius: 100px; padding: 6px 14px; font-size: 12px; background: #ffffff; color: #334155;\"\u003eCommercial Electrostatic Precipitator (ESP) Purifiers\u003c\/span\u003e \u003cspan style=\"border: 1px solid #cbd5e1; border-radius: 100px; padding: 6px 14px; font-size: 12px; background: #ffffff; color: #334155;\"\u003eHVAC Fan Coil Unit (FCU) In-Duct Electronic Filters\u003c\/span\u003e \u003cspan style=\"border: 1px solid #cbd5e1; border-radius: 100px; padding: 6px 14px; font-size: 12px; background: #ffffff; color: #334155;\"\u003eAir Handling Unit (AHU) Electronic Air Cleaners\u003c\/span\u003e \u003cspan style=\"border: 1px solid #cbd5e1; border-radius: 100px; padding: 6px 14px; font-size: 12px; background: #ffffff; color: #334155;\"\u003eCommercial Kitchen Range Hood Exhaust Purifiers\u003c\/span\u003e \u003cspan style=\"border: 1px solid #cbd5e1; border-radius: 100px; padding: 6px 14px; font-size: 12px; background: #ffffff; color: #334155;\"\u003eIndustrial Oil Mist Collectors \u0026amp; CNC Filtration\u003c\/span\u003e \u003cspan style=\"border: 1px solid #cbd5e1; border-radius: 100px; padding: 6px 14px; font-size: 12px; background: #ffffff; color: #334155;\"\u003eOEM Electronic Air Cleaner Appliance Manufacturing\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Section 7: OEM\/ODM Callout Banner --\u003e\n\u003cdiv style=\"background: #f8fafc; border-top: 3px solid #1773b0; padding: 18px 20px; border-radius: 0 0 4px 4px; border: 1px solid #e2e8f0; border-top-width: 3px;\"\u003e\n\u003ch3 style=\"margin: 0 0 6px 0; font-size: 15px; font-weight: bold; color: #0f172a;\"\u003eCustom OEM \u0026amp; ODM High-Voltage Manufacturing\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 12px 0; font-size: 12px; color: #475569; line-height: 1.6;\"\u003eBacked by 20+ years of high-voltage R\u0026amp;D and commercial manufacturing experience, KINYO offers extensive OEM\/ODM customization for ESP power supplies. Custom options include tailored input voltages (12VDC, 24VDC, 18VAC, 110VAC, 220VAC, 277VAC), customized dual-output voltage ratios (e.g., 6kV\/3kV, 10kV\/5kV), adjustable current limits up to 1mA+, custom wiring harness lengths and terminal lugs, customized mounting flanges, private label branding, and customized fault detection thresholds.\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.kinyo-china.com\/pages\/contact-us\" style=\"display: inline-block; background: #1773b0; color: #ffffff; text-decoration: none; padding: 8px 18px; border-radius: 4px; font-size: 12px; font-weight: 600;\"\u003eInquire About Custom OEM\/ODM Solutions →\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KINYO-CHINA","offers":[{"title":"180~250VAC","offer_id":46655952781558,"sku":null,"price":46.9,"currency_code":"USD","in_stock":true},{"title":"Custom OEM\/ODM Solution","offer_id":46655952978166,"sku":null,"price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0632\/0694\/9110\/files\/KYOG220V06_5W_high-voltage_power_supply_module_shown_from_an_open_top-down_view_on_a_white_background_highlighting_the_potted_internal_components_including_dual_toroidal_inductors_high-voltage_transformer_capacitor.jpg?v=1793002661","url":"https:\/\/www.kinyo-china.com\/en-au\/products\/kyog220v06","provider":"KINYO-CHINA","version":"1.0","type":"link"}